Product Overview
Tongdy
High-accuracy IAQ Monitor
with Flexible Sensor Selection
MSD - Commercial Grade for Intelligents & Green Buildings
(Model No.: MSD-09XXC/D)
Descriptions
Real-time collecting indoor air quality data of intelligent buildings/green buildings, also collecting outdoor data or official release data, upload the data to Cloud through monitoring analysis platform. Read and analyze the data using computer or cellphone. Achieve multi-parameter and all-direction real-time monitoring and assessment of indoor air quality, and use it to control building ventilation and air conditioning system, etc.
- 15 years design and production experience of IAQ (indoor air quality) products, long-term export to global markets, guaranteed by powerful strength.
- Sensor modular and silent design, flexible combination, detection up to 7 parameters with high cost and performance ratio.
- Provide a variety of wired and wireless communication interfaces, connect data collection platform and mobile phone, real-time data monitoring and analysis.
- Applied to fresh air systems and online monitoring of indoor air quality.
Features
- 24-hour online real-time online monitooring of indoor air quality, providing a choice of up to 7 parameters.
- PM2.5 & PM10, CO2, TVOC, temperature & humidity, CO / HCHO optional.
- The above sensor modular design allows you to select different monitoring parameters according to the application scenario
- Using own-patented technology, especially the built-in compensation of measuring value of environmental temperature and humidity, to ensure the accuracy and stability of monitoring value in different environments.
- The upgraded version of TVOC with big data operation is suitable for real-time on-line monitoring of TVOC concentration to avoid the impact of other factors leading to jump or deviation of measuring value.
- Silent design, suitable for rooms, personal offices and other noise-sensitive space.
- Two power supply modes: 12~28VDC/18~27VAC or 100~240VAC. The monitor could be connected to the BAS power, or used separately by municipal power supply.
- Three communication interface options are available: Modbus RS485 or RJ45, or WIFI.
- Select the working mode of the halo indicator. The indicator ring can indicate the indoor air quality level or turn it off.
- Mount the monitor on suspended ceiling or wall combining with technology and fashion with ease and simplicity to match with a variety of decorative styles. Monitor air quality evenly through air circulation.
- The special and core mulit-sensor module is inside, which is designed for the commercial grade monitors. The whole sealed case aluminum structure ensures the stability of detection and improves the anti-jamming capability.
Applications
- Online real-time detecting indoor air quality
- Green Building Assessment
- BAS and HVAC systems
- Smart Home System
- Fresh Air Controlling System
- Building Energy Saving Reconstruction and Assessment System
- Classroom, office, exhibition hall, shopping mall, any public places
Specification:
- PM2.5/PM10 Data
- Sensor: Laser partilce sensor, Light scattering method
- Measuring Range: PM2.5: 0~500μg/m3, PM10: 0~500μg/m3
- Output Resolution: 1μg∕㎥
- Accuracy: 15% of reading (0~300μg∕㎥)
- Life time: 5 years (Typical application)
- Carbon Dioxide (CO2) Data
- Sensor: Non-Dispersive Infrared Detector (NDIR), Life time and auto calibration
- Measurement Range: 0 ~ 5,000ppm
- Output Resolution: 1ppm
- Accuracy: ±50ppm + 3% of reading or ±75ppm (Whichever is bigger)
- Life time: > 10 years
- Total Volatile Organic Compounds (TVOC) Data
- Sensor: TVOC
- Measuring Range: 0~4.0mg/m3
- Output Resolution: 0.001mg/m3
- Accuracy: ±0.05mg+15% of reading
- Life time: ≥ 3 years
- Carbon Monoxide (CO) Data
- Sensor: Electrochemical CO Sensor
- Measurement Range: 0 ~ 100ppm (default)
- Output Resolution: 1ppm
- Accuracy: ±1ppm + 5% of reading
- Life time: ≥ 3 years
- Formaldehyde (HCHO) Data
- Sensor: Electrochemistry Formaldehyde sensor
- Measuring Range: 0~0.6mg/m3
- Output Resolution: 0.001mg∕m3
- Accuracy: ±0.005mg +5% of reading
- Life time: ≥ 3 years
- *Ozone (O3) Data (with specially customize sensor)
- Sensor: Electrochemical Ozone Sensor
- Measurement Range: 0 ~ 2000ug/m3 (0~2mg/m3)
- Output Resolution: 2 ug/m3
- Accuracy: ±20ug/m3 + 10% of reading (25℃, 10%~60%RH)
- Temperature and Humidity Data
- Sensor: Digital integrated temperature and humidity sensor
- Measuring Range: Temperature︰0℃~60℃ / Humidity︰0~99%RH
- Output Resolution: Temperature︰0.01℃ / Humidity︰0.01%RH
- Accuracy: Temperature︰±0.8℃@25℃ / Humidity︰±4.0%RH (20%~80%RH)
- Life time: > 10 years
- General Data
- Detection Data (Optional): Modular design sensor, up to 7 parameters (Max.)
- Temperature and humidity are standard.
- Optional parameters: PM2.5/PM10, CO2, TVOC, CO, O3 or HCHO
- Output:
- RS485/RTU (Modbus)
- RJ45/TCP (Ethernet)
- WiFi @2.4 GHz 802.11b/g/n
- Operating Environment: Temperature: 0~50℃ / Humidity︰0~99%RH
- Storage Conditions: -10℃~50℃ / 0~95%RH (No condensation)
- Power supply: 12~28VDC/18~27VAC or 100~240VAC
- Overall Dimension: 130mm(L) x 130mm(W) x 45mm(H)
- Material of Shell: PC/ABS fire-proof material
- IP Level: IP30
- Standard Approval: CE-Approval
- Detection Data (Optional): Modular design sensor, up to 7 parameters (Max.)
Products Models
Model | PM2.5 PM10 |
CO2 | Temp/RH | CO | TVOC | HCHO | Output |
Power Supply
|
MSD-0913C/D |
●
|
●
|
●
|
|
|
|
RS485
|
C/D
|
MSD-0914C/D |
●
|
●
|
●
|
●
|
|
|
RS485 |
C/D
|
MSD-0916C/D |
●
|
●
|
●
|
●
|
●
|
|
RS485
|
C/D
|
MSD-0917C/D |
●
|
●
|
●
|
|
|
●
|
RS485
|
C/D
|
MSD-0918C/D |
●
|
●
|
●
|
|
●
|
|
RS485
|
C/D
|
MSD-0919C/D |
●
|
●
|
●
|
|
●
|
●
|
RS485
|
C/D
|
MSD-0923C/D |
●
|
●
|
●
|
|
|
|
WIFI
|
C/D
|
MSD-0924C/D |
●
|
●
|
●
|
●
|
|
|
WIFI
|
C/D
|
MSD-0926C/D |
●
|
●
|
●
|
●
|
●
|
|
WIFI
|
C/D
|
MSD-0927C/D |
●
|
●
|
●
|
|
|
●
|
WIFI
|
C/D
|
MSD-0928C/D |
●
|
●
|
●
|
|
●
|
|
WIFI
|
C/D
|
MSD-0929C/D |
●
|
●
|
●
|
|
●
|
●
|
WIFI
|
C/D
|
MSD-0933C/D |
●
|
●
|
●
|
|
|
|
RJ45
|
C/D
|
MSD-0934C/D |
●
|
●
|
●
|
●
|
|
|
RJ45
|
C/D
|
MSD-0936C/D |
●
|
●
|
●
|
●
|
●
|
|
RJ45
|
C/D
|
MSD-0937C/D |
●
|
●
|
●
|
|
|
●
|
RJ45
|
C/D
|
MSD-0938C/D |
●
|
●
|
●
|
|
●
|
|
RJ45
|
C/D
|
MSD-0939C/D |
●
|
●
|
●
|
|
●
|
●
|
RJ45
|
C/D
|
C: 12~28VDC / 18~27VAC power supply
D: 100~240VAC power supply